Electrical design for houses and solar PV

Single line diagrams that design and check themselves

List the rooms and appliances. WiseSLD sizes every breaker and cable, balances the phases, checks voltage drop and earth-fault loop, prices three options — then lets you edit, ask, draw and mark up until it is right.

IEC 60364 and BS 767122 country presetsRuns in the browser
Two-storey villaStandard package · 3-phase 230/400 V 60 Hz · IEC 60364 · TN-S · max demand 44.5 kWUtility supplykWhMeterMain 100 A35 mm² Cu · 15 mMDB · Main board · 48-module (42 % spare)Surge protector Type 2M.1 · 10 A MCB R1 · 2.5 mm² · L1Water transfer pumpM.2 · 10 A RCBO · 2.5 mm² · L3Gate motorM.3 · 10 A RCBO · 1.5 mm² · L2Outdoor lighting3P 50 A · 10 mm² Cuto DB-1 Ground floor board3P 32 A · 4 mm² Cuto DB-2 First floor board1P 20 A · 2.5 mm² Cuto DB-3 Roof boardReserved: 6 modulesFrom main board3P 50 A · 10 mm² Cu · 8 mDB-1 · Ground floor board · 72-module (38 % spare)1.1 · 10 A MCB R1 · 1.5 mm² · L2Lighting 1 – Majlis, Living room1.2 · 10 A MCB R1 · 1.5 mm² · L3Lighting 2 – Dining, Kitchen, Guest bat…1.3 · 16 A RCBO · 2.5 mm² · L1Sockets 1 – Majlis1.4 · 16 A RCBO · 2.5 mm² · L1Sockets 2 – Living room1.5 · 16 A RCBO · 2.5 mm² · L2Sockets 3 – Dining, Guest bathroom, Bat…1.6 · 16 A RCBO · 2.5 mm² · L3Sockets 4 – Entrance & stairs1.7 · 20 A RCBO · 2.5 mm² · L2Kitchen sockets 1 – Kitchen1.8 · 16 A RCBO · 2.5 mm² · L2Outdoor sockets – Garden1.9 · 16 A MCB R1 · 4 mm² · L2AC 2 TR – Majlis1.10 · 16 A MCB R1 · 4 mm² · L1AC 2 TR – Living room1.11 · 16 A MCB R1 · 4 mm² · L2AC 1 TR – Dining1.12 · 16 A MCB R1 · 4 mm² · L3AC 1 TR – Kitchen1.13 · 16 A MCB R2 · 4 mm² · L1AC 1 TR – Maid / driver room1.14 · 16 A RCBO · 2.5 mm² · L1Water heater 11.15 · 16 A RCBO · 2.5 mm² · L2Water heater 21.16 · 16 A RCBO · 2.5 mm² · L3Water heater 31.17 · 16 A RCBO · 2.5 mm² · L3Oven1.18 · 32 A RCBO · 6 mm² · L3Cooktop1.19 · 16 A MCB R2 · 2.5 mm² · L1Dishwasher1.20 · 10 A MCB R2 · 2.5 mm² · L2Fridge / freezer 11.21 · 10 A MCB R2 · 2.5 mm² · L3Fridge / freezer 21.22 · 10 A MCB R2 · 2.5 mm² · L3Router / CCTV / securityFrom main board3P 32 A · 4 mm² Cu · 14 mDB-2 · First floor board · 48-module (25 % spare)2.1 · 10 A MCB R1 · 1.5 mm² · L2Lighting 1 – Master bedroom, Bedroom 2,…2.2 · 10 A MCB R1 · 1.5 mm² · L1Lighting 2 – Family room, Laundry, Corr…2.3 · 16 A RCBO · 2.5 mm² · L3Sockets 1 – Master bedroom2.4 · 16 A RCBO · 2.5 mm² · L1Sockets 2 – Bedroom 2, Bedroom 32.5 · 16 A RCBO · 2.5 mm² · L1Sockets 3 – Bedroom 4, Master bathroom,…2.6 · 16 A RCBO · 2.5 mm² · L2Sockets 4 – Family room, Laundry2.7 · 16 A RCBO · 2.5 mm² · L2Sockets 5 – Corridor & stairs2.8 · 16 A MCB R1 · 4 mm² · L2AC 1.5 TR – Master bedroom2.9 · 16 A MCB R1 · 4 mm² · L3AC 1 TR – Bedroom 22.10 · 16 A MCB R1 · 4 mm² · L1AC 1 TR – Bedroom 32.11 · 16 A MCB R1 · 4 mm² · L3AC 1 TR – Bedroom 42.12 · 16 A MCB R2 · 4 mm² · L3AC 1.5 TR – Family room2.13 · 16 A RCBO · 2.5 mm² · L2Water heater 12.14 · 16 A RCBO · 2.5 mm² · L3Water heater 22.15 · 16 A RCBO · 2.5 mm² · L2Water heater 32.16 · 16 A RCBO · 2.5 mm² · L1Washing machine2.17 · 16 A MCB R2 · 2.5 mm² · L1DryerFrom main board · on L21P 20 A · 2.5 mm² Cu · 20 mDB-3 · Roof board · 18-module (33 % spare)3.1 · 10 A MCB R1 · 1.5 mm² · L2Lighting 1 – Roof terrace, Roof store3.2 · 16 A RCBO · 2.5 mm² · L2Sockets 1 – Roof store3.3 · 16 A RCBO · 2.5 mm² · L2Outdoor sockets – Roof terrace3.4 · 10 A MCB R1 · 2.5 mm² · L2Water booster pumpSingle line diagram · WiseSLD · Rev ATwo-storey villaStatus0 fail · 2 warn · 31,603 SARMCB with R1, R2… = protected by shared RCD group. Circle = RCBO (own 30 mA RCD). Red = check failed. Dashed = reserved space. 0 failed checks Zs within limit · 46 circuits 💡 5 suggestions
22 roomsthree levels, entered in minutes
46 circuitson 4 boards, every one checked
44.5 kWmaximum demand → 100 A three-phase
3 optionspriced from 27,145 to 39,539 SAR

Ways to work

Start any way. Change it any way.

Every change — typed, clicked or drawn — is re-checked at once, and Undo works for all of them.

Design from rooms

Five short steps: house, rooms, appliances, backup and future, results.

All plans

Read a drawing

Upload a floor plan, an existing SLD photo or PDF, or describe it in words.

Starter and up

Edit

Change any circuit’s name, board, load, breaker, device, cable or length — or add your own circuits.

All plans

Improve

Suggestions that fix problems, make it safer or pay back through lower losses — apply one or all.

All plans · choice suggestions on Starter

Ask

Type “add a 7.4 kW EV charger” or “move the dryer to the main board”. See what it understood, then apply.

All plans

Revisions & resubmission

Save Rev A, B, C. Upload a resubmitted design and see every added, removed and changed circuit.

Starter and up

Draw

Place symbols, connect them and set ratings — or start from your design. Check the drawing in one click.

Starter and up

Mark up

Pin numbered notes on the drawing for redlines and site comments. They print on every export.

Starter and up

How it designs

A villa in Riyadh, from rooms to drawing

1

Rooms

22 rooms on three levels. Lighting, sockets and air conditioning come from each room type and area.

2

Load

66.2 kW connected, 44.5 kW at peak after diversity, so a 100 A three-phase service is enough.

3

Boards

46 circuits on a main board and one board per floor, balanced across the three phases.

4

Checks

Cable vs breaker after derating, voltage drop from the meter, earth-fault loop, selectivity, RCD and surge protection.

5

Options

Three priced packages, each choice costed — then edit, ask or draw to make it yours.

A · Economy27,145 SARLowest first cost · one RCD trip affects up to 8 circuits
B · Standard · recommended31,676 SARRCBOs where faults are likely, surge protection, solar and EV space
C · Future-ready39,539 SARRCBO on every circuit, essential board, solar and EV wired now

Sample villa in the app, material estimate excluding labour and tax. Every circuit is checked to clear an earth fault in time (estimated Zs from a typical Ze) — by its breaker, or by its 30 mA RCD where a long run needs it — as well as for current and voltage drop. Sub-board and main breakers are kept in size order so a fault trips only the nearest one.

Project types

Choose what you are designing first

House / villa

Rooms, appliances, AC, backup and future plans.

Available · all plans

Solar PV

Strings, inverters and cable runs, checked and improved.

Available · Starter

Apartment building

Flat templates, risers, landlord services and meters.

Coming · Pro

Commercial

Offices, shops, restaurants and clinics by space use.

Coming · Pro

Industrial

Motor lists, control panels and power factor.

Coming · Max

Compare

Where WiseSLD fits

Big analysis suites go deep on studies; solar platforms draw solar; calculator apps do loads. WiseSLD designs the whole building installation for you and keeps it editable.

WiseSLDPower-system analysis suitese.g. ETAP, EasyPower, SKMSolar design platformse.g. OpenSolar, Aurora, SurgePVLoad-calc & permit appse.g. KopperfieldDrawing & CAD toolse.g. AutoCAD Electrical, SmartDraw
Designs a building’s SLD from its roomsYesYou model each itemSolar side onlyTemplates and load calcsYou draw it
Sizes every breaker and cable, re-checks on changeYesYesSolar circuitsPanel schedulesNo
Priced options and lower-loss suggestions3 packages, each choice pricedStudy results; you decide changesVariesNoNo
Change it in plain wordsYes · AskNoSome toolsCode chatbotSome text-to-diagram tools
Read an existing drawing or planPhoto, PDF or wordsNoNoPanel photosNo
Draw, mark up, compare revisionsYesYesEditor in someDrawing and mark-upYes
Short-circuit, arc-flash, coordination studiesZs and selectivity estimatesIn depthNoNoNo
Cost to startFree, then from $15 a monthEnterprise licencesAnnual seatsMonthly plansLicence or subscription

From public product pages, November 2026. Features vary by edition; check each vendor for details. For utility-scale studies, arc-flash labels and protection coordination, a dedicated analysis suite remains the right tool.

Plans

Start free. Pay when it earns its keep.

Free

$0
to try it
  • 1 house, up to 3 levels
  • Standard option
  • Edit circuits and Ask in plain words
  • Improvement suggestions
  • PNG with a WiseSLD watermark
Try it free

Starter

$15
per month
  • Houses and solar PV
  • All options and choice-by-choice suggestions
  • Draw mode and mark-up notes
  • Revisions and resubmission compare
  • SVG, PNG and report, no watermark
  • Bill of quantities · 5 readings a month
Choose Starter
Most popular

Pro

$29
per month
  • Everything in Starter
  • Apartment buildings and commercial
  • Unlimited projects and revisions
  • PDF drawing set and Excel bill of quantities
  • Your own title block
  • 30 readings a month
Choose Pro

Max

$45
per month
  • Everything in Pro
  • Industrial projects
  • 3 users with shared projects
  • Company logo and branding
  • 100 readings a month
  • Priority support
Choose Max

Prices in US dollars, before tax. Apartment, commercial and industrial projects, the PDF set and Excel export are being added; plans that include them get them as they launch. Cancel any time; your projects stay readable.

Coming next

On the way

PDF drawing set

Drawing, schedules and checks in one set with your title block.

DXF / DWG export

Open the diagram in your CAD software.

Board photo reading

Photograph an existing board and get its circuit schedule.

Generator and battery sizing

Size backup from the essential loads you choose.

Fault-level study

Prospective fault current and selectivity with makers’ tables.

Team sharing and comments

Share a project; comments sit on the drawing.

NEC and more countries

US rules and more country presets.

Apartments, commercial, industrial

The next project types, in that order.

Questions

Does WiseSLD replace an electrical engineer?

No. It produces a complete, checked design quickly, with every assumption listed. Construction drawings still need review and sign-off by a licensed engineer where local rules require it.

Which standards does it follow?

IEC 60364 and BS 7671 today, with country presets for voltage, frequency, earthing and temperature. NEC is planned.

What are the different ways to change a design?

Edit any circuit in a table; apply Improve suggestions; Ask in plain words; save and compare Revisions, including a resubmitted file; Draw a diagram by hand or from your design; and Mark up the drawing with numbered notes. All are checked straight away and can be undone.

Does it check earth-fault loop impedance?

It estimates Zs for every circuit from a typical Ze for your earthing system and makes sure each circuit disconnects in time — by its breaker, or by its 30 mA RCD where a long run needs it. Ze and the prospective fault current must still be measured on site; every report says so.

Can I use my own prices?

Yes. Every rate in the bill of quantities is editable, in any currency, and so is the electricity tariff used for loss savings.

What can I do on the Free plan?

Design one house of up to three levels on the Standard option, edit its circuits, ask for changes in plain words and see improvement suggestions, with a watermarked PNG. Other options, Draw, Mark up, Revisions, clean downloads and drawing reading come with Starter.

Who can see my projects?

Only you, and the people you share a project with on the Max plan.

Design your first house in ten minutes

Free, no card. Your design stays in your browser until accounts open.

Start free